This Radio Frequency ,Twinaxial known as Data bus cable for application in Electronic Equipment and Systems. The cable is primarily intended for interconnection of various equipment/sub systems used in Digital command/Response Time Division Multiplexing techniques on Aircraft. The requirements for Data bus cable specified herein comply with the requirements of US Military Standard
MIL-STD-1553B: Digital Time Division Command/Response Multiplex Data Bus.
Shielding effectiveness: This cable is super shielded having a very low transfer Impedance for protection against the effects of an electromagnetic Pulse (EMP).
Size AWG |
Conductor Stranding n x mm |
Conductor diameter mm nomina |
Core Diameter mm |
Filler Diameter mm nominal |
Screen | Jacket Diameter mm maximum |
Maximum Weight g/m |
||
1 mm AWG |
2 mm |
3 mm AWG |
|||||||
24 | 19 x 0.12 | 0.60 | 1.08±0.05 | 0.80 | 0.10 38 |
Mumetal | 0.10 38 |
4.2 | 42 |
Impedance Ohms |
Velocity of propagation % Nom |
Capacitance Mutual pF/m maximum |
Attenuation dB/100 m maximum |
Surface transfer impedance milliohms/meter maximum |
Voltage withstanding V rms |
Insulation resistance Mohms-km minimum |
77 ± 5 | 69 | 70 | 4.0 at 1MHz | 0.2 at 30 MHz | 1000 | 1525 |
Reference standard : JSS 51034 , MIL-DTL-17H, MIL-DTL-27500H, MIL-C-17/203
Engineering note : Cable shall be suitable for use in MIL-STD-1553 data bus systems for use as main Bus or stub cable
Note : We can design same cable with different concluctor size
This Radio Frequency , Twinaxial known as Data bus cable for application in Electronic Equipment and Systems. The cable is primarily intended for interconnection of various equipment/sub systems used in Digital command/Response Time Division Multiplexing techniques on Aircraft. The requirements for Data bus cable specified herein comply with the requirements of US Military Standard
MIL-STD-1553B: Digital Time Division Command/Response Multiplex Data Bus.
Shielding effectiveness: This cable is super shielded having a very low transfer Impedance for protection against the effects of an electromagnetic Pulse (EMP).
Size AWG |
Conductor Stranding n x mm |
Conductor diameter mm nomina |
Core Diameter mm |
Filler | Screen | Jacket Diameter mm maximum |
Maximum Weight g/m |
||
1 mm AWG |
2 mm |
3 mm AWG |
|||||||
24 | 19 x 0.12 | 0.60 | 1.22±0.05 | 0.81±0.05 | 0.10 38 |
Mumetal | 0.10 38 |
4.1 | 43.30 |
Impedance Ohms |
Velocity of propagation % Nom |
Capacitance Mutual pF/m maximum |
Attenuation dB/100 m maximum |
Surface transfer impedance milliohms/mtr maximum |
Voltage withstanding V rms |
Insulation resistance Mohms-km minimum |
77 ± 5 | 61 | 68 | 4.6 at 1MHz | 1.0 at 30 MHz | 1000 | 1525 |
Reference standard : SAE-AS22759/35, MIL-DTL-17H, MIL-DTL-27500H, MIL-C-17/203
Engineering note : Cable shall be suitable for use in MIL-STD-1553 data bus systems for use as main Bus or stub cable